
Vincenzo Mariano MASTRONARDI
Ricercatore Universitario
Curriculum Vitae
Vincenzo M. Mastronardi received the M.S. degree in Ingegneria delle Telecomunicazioni in 2012 at the Università del Salento, Lecce (Italy). In 2016 he earned his Ph.D., carrying out the Doctoral program in Material Science and Technology at the Center for Biomolecular Nanotechnologies (IIT), Lecce (Italy) and received the degree of High Qualified Research Doctor in Nanotechnologies and Nanostructured Innovative Materials from Scuola Interpolitecnica di Dottorato (SIPD), Torino (Italy). From 2016 to 2021 he was a post-doc at the Center for Biomolecular Nanotechnologies (IIT), Lecce (Italy), working on implantable sensors based on Aluminum Nitride for monitoring heart activity, swallowing for early detection of dysphagia disease, and smart patches for monitoring vital parameters and sleep of astronauts. Since 2022 he is a researcher (RTDa) at the Department of Innovation Engineering of Università del Salento, Lecce (Italy), working on the design and testing of wearable sensors based on piezoresistive and piezoelectric materials and inertial sensors for monitoring human physiological parameters and joint movements. Moreover, his research interests include flexible and silicon-based MEMS, pressure and force sensors and piezoelectric energy harvester devices.
Didattica
A.A. 2022/2023
ELECTRONIC AND PHOTONIC DEVICES
Degree course COMMUNICATION ENGINEERING AND ELECTRONIC TECHNOLOGIES
Course type Laurea Magistrale
Language INGLESE
Credits 6.0
Owner professor VINCENZO MARIANO MASTRONARDI
Teaching hours Ore totali di attività frontale: 54.0
Ore erogate dal docente VINCENZO MARIANO MASTRONARDI: 27.0
Year taught 2022/2023
For matriculated on 2022/2023
Course year 1
Structure DIPARTIMENTO DI INGEGNERIA DELL'INNOVAZIONE
Subject matter PERCORSO COMUNE
Location Lecce
ELETTRONICA BIOMEDICA
Corso di laurea INGEGNERIA BIOMEDICA
Tipo corso di studio Laurea
Lingua ITALIANO
Crediti 9.0
Docente titolare Massimo DE VITTORIO
Ripartizione oraria Ore totali di attività frontale: 81.0
Ore erogate dal docente VINCENZO MARIANO MASTRONARDI: 27.0
Anno accademico di erogazione 2022/2023
Per immatricolati nel 2020/2021
Anno di corso 3
Struttura DIPARTIMENTO DI INGEGNERIA DELL'INNOVAZIONE
Percorso PERCORSO COMUNE
Sede Lecce
ELETTRONICA BIOMEDICA
Corso di laurea INGEGNERIA BIOMEDICA
Settore Scientifico Disciplinare ING-INF/01
Tipo corso di studio Laurea
Crediti 9.0
Docente titolare VINCENZO MARIANO MASTRONARDI
Ripartizione oraria Ore totali di attività frontale: 81.0
Ore erogate dal docente VINCENZO MARIANO MASTRONARDI: 27.0
Per immatricolati nel 2021/2022
Anno accademico di erogazione 2023/2024
Anno di corso 3
Semestre Primo Semestre (dal 18/09/2023 al 22/12/2023)
Lingua ITALIANO
Percorso PERCORSO COMUNE (999)
Sede Lecce
ELETTRONICA BIOMEDICA (ING-INF/01)
ELECTRONIC AND PHOTONIC DEVICES
Degree course COMMUNICATION ENGINEERING AND ELECTRONIC TECHNOLOGIES
Subject area ING-INF/01
Course type Laurea Magistrale
Credits 6.0
Owner professor VINCENZO MARIANO MASTRONARDI
Teaching hours Ore totali di attività frontale: 54.0
Ore erogate dal docente VINCENZO MARIANO MASTRONARDI: 27.0
For matriculated on 2022/2023
Year taught 2022/2023
Course year 1
Semestre Primo Semestre (dal 19/09/2022 al 16/12/2022)
Language INGLESE
Subject matter PERCORSO COMUNE (999)
Location Lecce
Background on solid state physics is recommended
The course deals with the working principle of the most important electronic devices (diodes, bipolar junction transistor, CMOS technology ...) and photonic devices (LED, Laser, optical fibers, photovoltaic devices ...).
It is organized in the following parts:
- Introduction on the solid state physics, energy bands and current transport mechanisms in semiconductors.
- Two terminal and three terminal electronic devices (p-n and Schottky junction diodes, bipolar transistors and MOSFETs
- light emitting and detecting photonic devices
The course also includes lectures on simulation of devices behavior.
Knowledge and understanding. Students must have a background in electromagnetic fields and waves and basic background in material science:
- the students must have the basic cognitive tools to understand semiconductor crystals and their electronic properties and apply this to understand how electrons move and distribute in a semiconductor device;
- they must have a solid knowledge of the electromagnetic waves and fields;
- they must be able to understand electric fields, potentials and voltages and electrostatic properties of materials;
- They must have a basic knowledge of electronic circuits, passive and active two- and three-terminals electronic devices.
Applying knowledge and understanding. After the course the student should be able to:
- understand what are the carrier transport, absorption and recombination mechanisms in semiconductor devices;
- understand how an electronic device works and what are the key parameters to design an efficient two terminal or three terminal electronic devices;
- design a LED or Laser device for different photonic applications;
- understand and design a photodetector.
Making judgements. Students are guided to learn critically everything that is explained to them in class, to understand the behavior of the state of the art technologies for electronic and photonic devices and to design new devices.
Communication. The students will be stimulated to be able to communicate with a varied and composite audience, not culturally homogeneous, in a clear, logical and effective way, using the methodological tools acquired and their scientific knowledge and, in particular, with and professional and scientific vocabulary.
Learning skills. Students must acquire the critical ability to understand the behavior of devices at the nanoscale. They should be able to develop and apply independently the knowledge and methods learnt with a view to possible continuation of studies at higher (doctoral) level or in the broader perspective of cultural and professional self-improvement of lifelong learning.
The teaching of the course will make use of both the blackboard and projection of videos and slides. Simulation of devices will be also done by exploiting freely available online tools.
Oral exam. The student is asked theoretical questions on each part of the course. During the discussion the student is asked to elaborate on the purpose of specific technological solutions in the design and fabrication of electronic devices and he/she is also asked to propose a different solution for a device with specific properties.
Solid State Physics
Physics of semiconductor materials, semiconductor technology, metal-semiconductor junction, p-n junction (12 hours).
Semiconductor Electronic devices
The Bipolar Junction Transistor (BJT), BJT working principle, BJT static and dynamic I-V characteristics, Models for BJT, The MOS Transistors and system, current-voltage characteristics of a MOSFET, MOSFET small and large signal models (22 hours).
Photonic devices
Optical processes in semiconductors, the LED, the LASER, laser waveguide and resonant cavities, material gain, type of semiconductor lasers, optical detectors and photovoltaic devices (20 hours).
[1] Lecture notes
[2] S.M. Sze, Semiconductor Devices: Physics and Technology, Bell Tel.Labs.Inc.
[3] R.S. Muller-T.I. Kamins, Dispositivi Elettronici nei Circuiti Integrati, Boringhieri
[4] Ghione G., Dispositivi per la Microelettronica, McGraw Hill.
ELECTRONIC AND PHOTONIC DEVICES (ING-INF/01)
ELETTRONICA BIOMEDICA
Corso di laurea INGEGNERIA BIOMEDICA
Settore Scientifico Disciplinare ING-INF/01
Tipo corso di studio Laurea
Crediti 9.0
Docente titolare Massimo DE VITTORIO
Ripartizione oraria Ore totali di attività frontale: 81.0
Ore erogate dal docente VINCENZO MARIANO MASTRONARDI: 27.0
Per immatricolati nel 2020/2021
Anno accademico di erogazione 2022/2023
Anno di corso 3
Semestre Primo Semestre (dal 19/09/2022 al 16/12/2022)
Lingua ITALIANO
Percorso PERCORSO COMUNE (999)
Sede Lecce
Concetti appresi nei corsi di Fisica Generale II e Principi di Ingegneria Elettrica
Fondamenti di elettronica analogica e digitale. Tipologie di segnali in ambito biomedico. Acquisizione ed elaborazione di un segnale. Architetture e caratteristiche dei dispositivi e della strumentazione elettronica nell'Ingegneria Biomedica.
L'obiettivo primario del corso è fornire le conoscenze necessarie a comprendere ed utilizzare le più recenti tecnologie elettroniche relative ai dispositivi, circuiti e strumentazione per applicazioni biomediche. Più in dettaglio, il corso è concepito per fornire allo studente le opportune conoscenze per l’analisi nel dominio del tempo e della frequenza di diversi bio-segnali, per la comprensione dei principi di funzionamento dei dispositivi per l’acquisizione di segnali di natura biomedica e delle principali soluzioni circuitali per il condizionamento dei bio-segnali. Lo studente dunque al termine del corso sarà in grado di comprendere lo schema generale di uno strumento o dispositivo biomedico (anche di tipo indossabile o impiantabile nella persona) ed individuare i fattori che ne influenzano il funzionamento anche al fine di una successiva progettazione.
Lezioni frontali in aula ed attività laboratoriale
Prova scritta sugli argomenti del corso ed esame orale (opzionale).
Fondamenti di elettronica analogica e digitale
Segnali analogici e digitali. Richiami sui teoremi delle reti elettriche. Cenni sui principali dispositivi elettronici: diodo, transistor ed amplificatore operazionale. Rappresentazione digitale dell’informazione e porte logiche fondamentali.
Trattamento di segnali in ambito biomedico
Analisi dei segnali nel dominio del tempo e della frequenza. Grandezze elettriche fondamentali di un segnale. Aspetti generali sul filtraggio di un segnale: differenti tipologie di filtri analogici. Richiami sul teorema di Shannon: campionamento e quantizzazione di un segnale. Conversione analogico-digitale di un segnale. Caratteristiche dei principali segnali biomedici (segnale elettrocardiografico ECG, elettromiografico EMG, elettroencefalografico EEG, etc …). Stadi di condizionamento ed amplificazione di un segnale analogico. Canale di acquisizione ed elaborazione di un segnale. Circuiti di protezione e isolamento di un’apparecchiatura bio-medicale.
Caratteristiche della strumentazione biomedica e relativi dispositivi
Bioingegneria e ruolo della strumentazione biomedica. Architetture dei dispositivi e della strumentazione elettronica nell'Ingegneria Biomedica. Caratteristiche della strumentazione e specifiche dei sistemi di misura: parametri generali di sensori e trasduttori tipicamente usati nelle apparecchiature bio-medicali. Principi di funzionamento dei principali dispositivi per l’acquisizione di grandezze meccaniche, elettriche e termiche in ambito biomedico. Misure di bio-segnali elettrici, fisici (forza e pressione) e della temperatura corporea ed ambientale. Dispositivi per l’analisi cinematica e dinamica del movimento umano - cenni applicativi. Dispositivi biomedici indossabili o impiantabili nella persona per il monitoraggio di funzioni vitali e biometria. Sistemi di trasmissione wireless di segnali biomedici.
- Note sugli argomenti del corso da parte del docente
- Guide per esercitazione di laboratorio
- "Microelectronic Circuits”, by A. S. Sedra, K. C. Smith
- “Analysis and Application of Analog Electronic Circuits to Biomedical Instrumentation”, by Robert B. Northrop.
- “Biomedical Sensors and Instruments”, by Tatsuo Tagawa, Toshiyo Tamura, P. Ake Oberg.
- “Circuits, Signals and Systems for Bioengineers”, by John Semmlow.
ELETTRONICA BIOMEDICA (ING-INF/01)
Pubblicazioni
1) Guido F., Mastronardi V.M., Todaro M.T., Petroni S., De Vittorio M., "Piezoelectric soft MEMS
for tactile sensing and energy harvesting.", 2014 IEEE INTERNATIONAL CONFERENCE ON
IC DESIGN & TECHNOLOGY (ICICDT), ISBN: 978-147992153-9, DOI:
10.1109/ICICDT.2014.6838623, Scopus: 2-s2.0-84904206996, WOS: 000358796500044,
(2014).
2) Mastronardi V. M., Guido F., De Vittorio M. Petroni S., "Flexible force sensor based on c-axis
oriented aluminum nitride.", Procedia Engineering, 28TH EUROPEAN CONFERENCE ON
SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), ISSN: 1877-7058, Vol. 87, pp. 164 –
167, DOI: 10.1016/j.proeng.2014.11.609, Scopus: 2-s2.0-84923379215, WOS:
000369531700039, (2014);
3) Mastronardi V. M., Guido F., Amato M., De Vittorio M. Petroni S., "Piezoelectric ultrasonic
transducer based on flexible AlN", Microelectronic Engineering, ISSN: 0167-9317, Vol. 121,
pp. 59 – 63, DOI: 10.1016/j.mee.2014.03.034, Scopus: 2-s2.0-84898933812, WOS:
000341471500015, (2014);
4) Mastronardi V. M., Ceseracciu L., Guido F., Rizzi F., Athanassiou A., De Vittorio M., Petroni
S., "Low stiffness tactile transducers based on AlN thin film and polyimide.", Applied Physics
Letters, ISSN: 0003-6951, Vol. 106, Issue 16, DOI: 10.1063/1.4918749, Article Number:
162901, Scopus: 2-s2.0-84928472967, WOS: 000353559900028, (2015);
5) Petroni S., Rizzi F., Guido F., Cannavale A., Donateo T., Ingrosso F., Mastronardi V.M.,
Cingolani R., De Vittorio M., “Flexible AlN flags for efficient wind energy harvesting at ultralow
cut-in wind speed”, RSC Advances, ISSN 20462069, Vol. 5, Issue 18, pp. 14047 – 14052, DOI:
10.1039/c4ra10319j, Scopus: 2-s2.0-84922566637, WOS: 000349434300098, (2015);
6) Mastronardi V. M., Abels C., Guido F., Dattoma T., Qualtieri A., Megill W. M., De Vittorio M.,
Rizzi F., "Nitride-Based Materials for Flexible MEMS Tactile and Flow Sensors in Robotics",
Sensors, ISSN: 1424-8220, Vol. 17, Issue 5, DOI: 10.3390/s17051080, Article Number: 1080,
Scopus: 2-s2.0-85056886799, WOS: 000404553300141, (2017);
7) Todaro M. T., Guido F., Mastronardi V. M., Desmaele D., Epifani G., Algieri L., De Vittorio M.,
"Piezoelectric MEMS vibrational energy harvesters: Advances and outlook”, Microelectronic
Engineering, ISSN: 0167-9317, Vol. 183, pp. 23-36, DOI: 10.1016/j.mee.2017.10.005,
Scopus: 2-s2.0-85031113480, WOS: 000417666700004, (2017);
8) Algieri L., Todaro M.T., Guido F., Mastronardi V.M., Desmaele D., Qualtieri A., Giannini C.,
Sibillano T., De Vittorio M., “Flexible Piezoelectric Energy-Harvesting Exploiting
Biocompatible AlN Thin Films Grown onto Spin-Coated Polyimide Layers”, ACS Applied
Energy Materials, ISSN: 2574-0962, Vol. 10, Issue 10, pp. 5203-5210, DOI:
10.1021/acsaem.8b00820, Scopus: s2.0-85059753753, WOS: 000458706600014, (2018);
9) Todaro M.T., Guido F., Algieri L., Mastronardi V.M., Desmaele D., Epifani G., De Vittorio M.,
"Biocompatible, Flexible, and Compliant Energy Harvesters Based on Piezoelectric Thin
Films”, IEEE Transactions on Nanotechnology, ISSN: 1536-125X, Vol. 17, Issue 2, pp. 220-
230, DOI: 10.1109/TNANO.2017.2789300, Scopus: 2-s2.0-85040085142, WOS:
000427251000005, (2018);
10) Natta L., Mastronardi V.M., Guido F., Algieri L., Puce S., Pisano F., Rizzi F., Pulli R., Qualtieri
A., De Vittorio M., “Soft and flexible piezoelectric smart patch for vascular graft monitoring
based on Aluminum Nitride thin film”, Scientific Report, ISSN: 2045-2322, Vol. 9, DOI:
10.1038/s41598-019-44784-1, Article Number: 8392, Scopus: 2-s2.0-85067190539, WOS:
000470847000016, (2019);
11) Mariello M., Guido F., Mastronardi V.M., Giannuzzi R., Algieri L., Qualteri A., Maffezzoli A.,
De Vittorio M., “Reliability of protective coatings for flexible piezoelectric transducers in
aqueous environments”, Micromachines, eISSN2072-666X, Vol. 10, Issue 11, DOI:
10.3390/mi10110739, Article Number: 739, Scopus: 2-s2.0-85075557648, WOS:
000502255300025, (2019);
12) L. Natta; V. M. Mastronardi; F. Guido; L. Algieri; S. Puce; F. Pisano; F. Rizzi; R. Pulli; A.
Qualtieri; M. De Vittorio, “Aluminium Nitride based bio-MEMS for vascular graft monitoring”,
22nd European Microelectronics and Packaging Conference & Exhibition (EMPC), ISSN:
2165-2341, ISBN: 978-095680866-0, Book Series: European Microelectronics Packaging
Conference, DOI: 10.23919/EMPC44848.2019.8951796, Scopus: 2-s2.0-85078855732,
WOS: 000532694100024, (2019);
13) Mariello M., Guido F., Mastronardi V.M., Todaro M.T., Desmaele D., De Vittorio M.,
”Nanogenerators for harvesting mechanical energy conveyed by liquids”, Nano Energy, ISSN:
2211-2855, Vol. 57, pp. 141 – 156, DOI: 10.1016/j.nanoen.2018.12.027, Scopus: 2-s2.0-
85058523653, WOS: 000458419000014, (2019);
14) Mariello M., Guido F., Mastronardi V.M., De Donato F., Salbini M., Brunetti V., Qualtieri A.,
Rizzi F., De Vittorio M., “Captive-air-bubble aerophobicity measurements of antibiofouling
coatings for underwater MEMS devices”, Nanomaterials and Nanotechnology, ISSN: 1847-
9804, Vol. 9, DOI: 10.1177/1847980419862075, Article Number: 1847980419862075,
Scopus: 2-s2.0-85069794295, WOS: 000477862600001, (2019);
15) Lamanna L., Rizzi F., Guido F., Algieri L., Marras S., Mastronardi V.M., Qualtieri A., De
Vittorio M., “Flexible and Transparent Aluminum‐Nitride‐Based Surface‐Acoustic‐Wave
Device on Polymeric Polyethylene Naphthalate”, Advanced Electronic Materials, ISSN: 2199-
160X, Vol. 5, Issue 6, DOI10.1002/aelm.201900095, Article Number: 1900095, Scopus: 2-
s2.0-85065651136, WOS: 000471049100022, (2019);
16) Algieri L., Todaro M.T., Guido F., Blasi L., Mastronardi V.M., Desmaele D., Qualtieri A.,
Giannini C., Sibillano T., De Vittorio M., “Piezoelectricity and Biocompatibility of Flexible
ScxAl(1- x)N Thin Films for Compliant MEMS Transducers”, ACS Applied Materials and
Interfaces, ISSN: 1944-8244, Vol. 12, Issue 16, pp. 18660 – 18666, DOI:
10.1021/acsami.0c00552, Scopus: 2-s2.0-85084027290, WOS: 000529202100048,
(2020);
17) Scarpa E., Mastronardi V. M., Guido F., Algieri L., Qualtieri A., Fiammengo R., Rizzi F., De
Vittorio M., “Wearable piezoelectric mass sensor based on pH sensitive hydrogels for sweat pH
monitoring”, Scientific Reports, ISSN: 20452322, Vol.10, Issue 1, DOI: 10.1038/s41598-
020-67706-y, Article number: 10854, Scopus: 2-s2.0-85087304860, WOS:
000549994800050, (2020);
18) Abdul B., Mastronardi V.M., Qualtieri A., Algieri L., Guido F., Rizzi F., De Vittorio M.,
“Sensitivity and directivity analysis of piezoelectric ultrasonic cantilever-based mems
hydrophone for underwater applications”, Journal of Marine Science and Engineering, ISSN:
2077-1312, Vol. 8, Issue 10, DOI: 10.3390/jmse8100784, Article Number: 784, Scopus: 2-
s2.0-85093068091, WOS: 000586926800001, (2020);
19) Mariello M., Scarpa E., Algieri L., Guido F., Mastronardi V.M., Qualtieri A., De Vittorio M.,
“Novel flexible triboelectric nanogenerator based on metallized porous PDMS and Parylene
C”, Energies, ISSN: 19961073, Vol. 13, Issue 7, DOI: 10.3390/en13071625, Article number:
en13071625, Scopus: 2-s2.0-85082752232, WOS: 000537688400094, (2020);
20) Abdul B., Mastronardi V.M., Qualtieri A., Guido F., Algieri L., Rizzi F., De Vittorio M., “Design,
fabrication and characterization of piezoelectric cantilever MEMS for underwater
application”, Micro and Nano Engineering, ISSN: 2590-0072, Vol.7 DOI:
10.1016/j.mne.2020.100050, Article number: 100050, Scopus: 2-s2.0-85082838136, WOS:
000579774300002, (2020);
21) Marasco I., Niro G., Lamanna L., Piro L., Guido F., Algieri L., Mastronardi V.M., Qualtieri A.,
Scarpa E., Desmaele D., Rizzi F., D'Orazio A., De Vittorio M., Grande M., “Compact and flexible
meander antenna for Surface Acoustic Wave sensors”, Microelectronic Engineering, ISSN:
0167-9317, Vol. 227, DOI: 10.1016/j.mee.2020.111322, Article Number: 111322, Scopus:
2-s2.0-85083563730, WOS: 000531097600013, (2020);
22) Mariello M., Blad T.W.A., Mastronardi V.M., Madaro F., Guido F., Staufer U., Tolou N., De
Vittorio M., “Flexible piezoelectric AlN transducers buckled through package-induced
preloading for mechanical energy harvesting”, Nano Energy, ISSN: 2211-2855, Vol. 85, DOI:
10.1016/j.nanoen.2021.105986, Article Number: 105986, Scopus: 2-s2.0-85103116294,
WOS: 000663442000002, (2021); Vincenzo Mariano Mastronardi
23) De Bartolo S., De Vittorio M., Francone A., Guido F., Leone E., Mastronardi V.M., Notaro A.,
Tomasicchio G.R., “Direct scaling of measure on vortex shedding through a flapping flag
device in the open channel around a cylinder at re ≈ 10 3 : Taylor’s law approach”, Sensors,
ISSN: 1424-8220, Vol. 21, Issue 5, DOI: 10.3390/s21051871, Article Number: 18712021,
Scopus: 2-s2.0-85102115485, WOS: 000628578900001, (2021);
24) Natta L., Guido F., Algieri L., Mastronardi V.M., Rizzi F., Scarpa E., Qualtieri A., Todaro M.T.,
Sallustio V., De Vittorio M., “Conformable AlN Piezoelectric Sensors as a Non-invasive
Approach for Swallowing Disorder Assessment”, ACS Sensors, ISSN: 2379-3694, Vol. 6, Issue
5, pp. 1761 – 1769, DOI: 10.1021/acssensors.0c02339, Scopus: 2-s2.0-85107238742, WOS:
000657373200008, (2021);
25) Mariello M., Guido F., Algieri L., Mastronardi V. M., Qualtieri A., Pisanello F., De Vittorio M.,
“Microstructure and Electrical Properties of Novel piezo-optrodes Based on Thin-Film
Piezoelectric Aluminium Nitride for Sensing”, in IEEE Transactions on Nanotechnology, ISSN
1536-125X, EISSN: 1941-0085, Vol. 20, pp. 10-19, DOI: 10.1109/TNANO.2020.3042234,
Accession Number: 20265397, Scopus: 2-s2.0-85098803182, WOS: 000604827800002,
(2021);
26) De Marzo G., Desmaele D., Algieri L., Natta L., Guido F., Mastronardi V.M., Mariello M.,
Todaro M. T., Rizzi F., De Vittorio M., “Chitosan-Based Piezoelectric Flexible and Wearable
Patch for Sensing Physiological Strain”, Engineering Proceedings, EISSN: 2673-4591, Vol. 6,
Issue 1, Article Number: 122021 (2021);